<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-29 04-05-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 4/5, 43 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 16 kHz 3537 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,77 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 4:05, 29.01.2024
RT
"Knizky Plus - Jak zivy je odkaz spisovatele a skauta Jaroslav..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 16 kHz MIN: 6 kHz % above 77 kHz: 0,0000 Acquired: 2024/01/29 4:05:45 Total samples: 3537 Equivalent time: 0:02:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,0 dBr MIN: -1,2 dBr AVE: -0,77 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2024/01/29 4:05:45) 03:52 03:54 03:56 03:58 04:00 04:02 04:04 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality